- 3-Way 2-Position
- 2-Way 2-Position 3-Way 2-Position 4-Way 2-Position 4-Way 3-Position 5-Way 3-Position
Up all
Pack up all
-
Technical Feature
OPERATION:
When de-energized, the valve allows flow from ② to ③ , while blocking flow at ① .
When energized, the cartridge's poppet shifts to allow flow from ① to ② , while
blocking flow at ③ .Operation of Manual Override Option:
To override, push button in, twist counterclockwise 180°and release. In this position,
valve will remain detented in the shifted condition. To return to normal operation, push
button in, twist clockwise 180°and release. Override will be detented in this position. -
Technical Data
24barSee PRESSURE DROP VS.FLOW graph.08-3SRefer to "Cleanliness of Hydraulic Fluid"2 drops/min. max. at 24bar-40°F to +212°F(-40°C to +100°C)Continuous from 85% to 115% of nominal voltageMineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES
Coil