A cartridge-style poppet-type,normally closed, pilot unloading valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION

    In its steady state, the valve blocks flow from port to port ,until either the
    predetermined spring setting has been reached at port
    , or an external pilot has
    been applied to port
    . At this time flow is then allowed from port to port .
    Since the spring chamber is vented at port
    , back pressure at port will directly (1:1)
    effect the valve setting.

  • PerformanceCurves

    曲线.png

  • Technical Data

    Operating Pressure
    210bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    10-3
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    ① to ②:2drops/min Max.at 210bar
    Standard Spring Ranges
    20.7 to 103bar; Preset: 62bar
    103 to 207bar; Preset: 155bar
    Temperature
    -40ºF to +250ºF(-40ºC to +120ºC)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar