Up all
Pack up all
-
Technical Feature
OPERATION:
These unbalanced, vent-to-open logic valves are 2-way switching elements that are
spring-biased closed and incorporate an integral shuttle so that the higher of pressures
at either port ① or port ② can be used as a pilot source. With port ③ blocked, the valve
is held in the closed position by the spring force. With port ③ vented, the valve will open
provided there is sufficient pressure to overcome the spring force. The force generated at
port ③ , plus the spring force, must be greater than the sum of the forces acting at port ①
and port ③ for the valve to remain closed. NOTE: The pilot area (port ③ ) is 1.8 times the
area at port ① and 2.25 times the area at port ② . -
PerformanceCurves
-
Technical Data
See PRESSURE DROP VS.FLOW graph.SUN T-17ARefer to "Cleanliness of Hydraulic Fluid"350bar10 drops/min. max.-40ºF to +250ºF(-40ºC to +120ºC)Mineral-based fluids with viscosities of 7.4 to 420 cSt.Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES