Up all
Pack up all
-
Technical Feature
OPERATION:
The valve is a direct-acting, dual cross-over relief valve in a single cartridge format. When
pressure at either port exceeds the nominal setting value, flow will be transmitted to the
opposite port. Back pressure at either port will affect the nominal setting of the opposite
port on a 1 :1 basis.
For correlation purposes, pre-set value will be measured at port ② .Pressure at port ① will
not exceed ±150 psi from the port ② value. -
PerformanceCurves
-
Technical Data
207BarSee PRESSURE DROP VS.FLOW graph.10-2Refer to "Cleanliness of Hydraulic Fluid"when reseat to 80% of cracking Pressure: 33 ml/min.(crack pressure at 0.95 lpm /0.25 gpm)80% of crack pressure10.5 bar (150 psi)pressure is set at port② , 14 to 168 bar; 100 to 210 bar;-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES