LACRV2-16

PDF Download

Description

A cartridge-style pilot-operated poppet -type relief valve with reverse free flow check

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    The valve prevents flow from to until pressure at exceeds the set
    Cracking Pressure and opens the pilot section. The pilot flow creates a pressure
    differential across the poppet which causes the valve to open allowing flow from
    to protecting the circuit from over pressurization.
    Pressure at
    overcomes the spring-bias pressure 2 3bar and allows free flow
    from
    to .

  • PerformanceCurves

    ll.png

  • Technical Data

    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    16-2
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Max.Operating Pressure
    350Bar
    Internal Leakage
    10 drops/min max. to 80% of nominal setting
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar