- Relief Valves
- Relief Valves Reducing Valves Sequence Valves Pilot Unloading Valves
Up all
Pack up all
-
Technical Feature
OPERATION:
Flow is free from ① to ② until pressure increases to meet the selected valve setting, allowing
relief flow through port ① to tank. This valve combines the typical function of shock relief valve
(direct acting) and anticavitation function through the check valve. The direct action and the
specific design allow a very fast opening and closing.
Note: to obtain a good leak proof performances coin the cavity seat using a loose valve seat as a
coning tool.
Torque to be applied :6.5 ± 2 Nm. -
PerformanceCurves
-
Technical Data
FlowSee PRESSURE DROP VS.FLOW graph.CavityRexroth-870FiltrationRefer to "Cleanliness of Hydraulic Fluid"Max.Operating Pressure400BarMax.Flow90 l/min.Standard Spring Ranges90 to 140 bar;
140 to 270bar;
270 to 350bar;
350 to 400bar;Temperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body MaterialSteel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES