Description

A cartridge-style direct-acting poppet-type anti-cavitation relief valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    Flow is free from to until pressure increases to meet the selected valve settingallowing
    relief flow through port
    to tank. This valve combines the typical function of shock relief valve
    (direct acting) and anticavitation function through the check valve. The direct action and the
    specific design allow a very fast opening and closing.
    Note: to obtain a good leak proof performances coin the cavity seat using a loose valve seat as a
    coning tool.
    Torque to be applied :6.5 ± 2 Nm.

  • PerformanceCurves

    ll.png

  • Technical Data

    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    Rexroth-870
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Max.Operating Pressure
    400Bar
    Max.Flow
    90 l/min.
    Standard Spring Ranges
    90 to 140 bar;
    140 to 270bar;
    270 to 350bar;
    350 to 400bar;
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar