OPERATION:
Low-side (hot oil) shuttle cartridges allow hot oil to be diverted from the low pressure
side of a closed loop system. When both work ports (ports ② and ④ )are at equal
pressures the valve is spring-centered to an all-ports-blocked position. When one
of the work ports(port ② or ④ )sees a higher pressure the opposite work port is
connected to the common port(port ③ ). -
PerformanceCurves
-
Technical Data
Operating Pressure350barFlowSee PRESSURE DROP VS.FLOW graph.CavitySUN T-31AFiltrationRefer to "Cleanliness of Hydraulic Fluid"Temperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body MaterialSteel & Ductile iron rated to 350bar -