Up all
Pack up all
-
Technical Feature
OPERATION:
In its steady-state, spring-offset position, the valve directs flow from ③ to ② , and from
④ to ① . In the actuated (pulled) position, the cartridge directs flow from ③ to ④ ,and
from ② to ① . The spring chamber is vented at ① .
Note: Pressure at port ① will directly act on the spool and spring. Port ① is
intended to be a tank port only. Series operation is prohibited due to the tank port
① pressure rating.
A unique pull-and-rotate feature for holding the positive actuated position is optional.
A 90° rotation is required to position at the hold slot. The valve resets to spring-return
de-actuated with a slight pull and a 90° turn from the locked actuated position. -
PerformanceCurves
-
Technical Data
207bar
On②,③and④ 240bar
On①Max.14barSee PRESSURE DROP VS.FLOW graph.08-4Refer to "Cleanliness of Hydraulic Fluid"82 cc/min max.-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES