LMP-08-L

PDF Download

Description

A cartridge-style manual 2-way pull-to-open directional valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    The valve blocks flow to until an operator pulls the shaft outward.
    A unique pull-and-rotate feature for holding the positive actuated position is optional. A 90°rotation is required to position at the hold slot. The valve resets to spring-return deactuated with a slight pull and a 90°turn from the locked actuated position.

  • PerformanceCurves

    ll.png

  • Technical Data

    Operating Pressure
    210Bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    08-2
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    5 drops/min max. at 210bar
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar