Up all
Pack up all
-
Technical Feature
OPERATION:
Unpiloted, the valve blocks flow from ③ to ② bidirectionally.V is a spring chamber vent-to-atmosphere, which is internally O-ring sealed from the cartridge flow paths.On remote pilot signal at ① , the valve shifts to open ② to ③ bidirectionally.
Because of the vented spring chamber, the cartridge may be fully pressurized at any port without affecting required pilot pressure.
-
PerformanceCurves
-
Technical Data
240BarSee PRESSURE DROP VS.FLOW graph.10-3Refer to "Cleanliness of Hydraulic Fluid"82cc/min. max. at 240barTo Full Spool Shift:
for 4.1bar spring: 4.7bar
for 7.6bar spring: 8.6bar-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES