Up all
Pack up all
-
Technical Feature
OPERATION:
The valve allows flow from ② to ① , while normally blocking flow from ① to ② . Flow will be allowed from ① to ② when sufficient pressure is applied at port “P”.
The cartridge has a 3:1 pilot ratio, meaning that at least one-third of the load pressure held at ① is required at “P” to open the valve.
-
PerformanceCurves
-
Technical Data
Operating Pressure350BarFlowSee PRESSURE DROP VS.FLOW graph.Cavity10-2FiltrationRefer to "Cleanliness of Hydraulic Fluid"Internal Leakage2 drops/min. max. at 350barCrack Pressures2.1=2.1bar
4.2=4.2bar
8.4=8.4barPilot Ratio3:1Temperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body MaterialSteel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES