OPERATION:
Pressure at ① overcomes the spring-bias poppet and allows free flow from ① to ② .
Flow in the opposite direction, from ② to ① ,is blocked by the poppet. -
PerformanceCurves
-
Technical Data
Operating Pressure250barFlowSee PRESSURE DROP VS.FLOW graph.Cavity08-2FiltrationRefer to "Cleanliness of Hydraulic Fluid"Internal Leakage2 drops/min. max. at 250barCrack Pressures0.3=0.3bar
0.7=0.7bar
2.1=2.1bar
3.0=3.0bar
4.1=4.1bar
6.9=6.9barTemperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body Material6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -