LFR-M14

PDF Download

Description

A cartridge-style, non-adjustable, pressure-compensated flow control valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    The valve maintains a constant flow within specified accuracies from to regardless
    of downstream load pressure. When flow produces a minimum predetermined pressure
    differential across the compensator spool control orifice, the spool shifts against the
    spring force to throttle the flow and maintain the flow setting. Reverse flow is not
    regulated.


  • PerformanceCurves

    ll.png

  • Technical Data

    Operating Pressure
    420bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    Rexroth-R/DBD.4k
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Flow Setting
    0.4-0.8-1.2 l/min.
    Flow Maintenance Accuracy
    ±15%
    Temperature
    -40ºF to +250ºF(-40ºC to +120ºC)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar
  • File Download

    PDF File
  • ACCESSORIES

Contact Us