- Relief Valves
- Relief Valves Reducing Valves Sequence Valves Pilot Unloading Valves
Up all
Pack up all
-
Technical Feature
OPERATION:
Flow is free from ① to ② until pressure increases to meet the selected valve setting, allowing
relief flow through port ① to tank. This valve combines the typical function of shock relief valve
(direct acting) and anti-cavitation function through the check valve. The direct action and the
specific design allow a very fast opening and closing.
Note: to obtain a good leak proof performance coin the cavity seat using a loose valve seat as a
coning tool. Torque to be applied : 4.5 ± 2 Nm. -
PerformanceCurves
-
Technical Data
See PRESSURE DROP VS.FLOW graph.VH003Refer to "Cleanliness of Hydraulic Fluid"420bar75L/min15 drops/min max. to 80% of nominal setting20 to 100 bar;
101 to 170 bar;
171 to 250 bar;
251 to 350 bar;
351 to 420 bar;-40ºF to +250ºF(-40ºC to +120ºC)Mineral-based fluids with viscosities of 7.4 to 420 cSt.Steel & Ductile iron rated to 350bar -