Technical Feature
OPERATION:
Low-side (hot oil) shuttle cartridges allow hot oil to be diverted from the low pressure
side of a closed loop system. When both work ports (ports ② and ④ )are at equal
pressures the valve is spring-centered to an all-ports-blocked position. When one
of the work ports(port ② or ④ )sees a higher pressure the opposite work port is
connected to the common port(port ③ ). -
PerformanceCurves
-
Technical Data
350barSee PRESSURE DROP VS.FLOW graph.10-4Refer to "Cleanliness of Hydraulic Fluid"-40ºF to +250ºF(-40ºC to +120ºC)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -