OPERATION:
Without air pressure on ③, the valve acts as a check valves, allowing flow from ① to ②,
while blocking flow from ② to ① .
With air pressure on ③ , the poppet lifts to open the ② to ① flow path. In this mode,
flow is also allowed from ① to ② . -
PerformanceCurves
-
Technical Data
210barSee PRESSURE DROP VS.FLOW graph.16-2Refer to "Cleanliness of Hydraulic Fluid"3 drops/min max. at 210 bar-40ºF to +250ºF(-40ºC to +120ºC)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES