Up all
Pack up all
-
Technical Feature
OPERATION:
In neutral position(unpiloted), the valve allows flow from port ③ to ② bidirectionally, while port ④ is blocked. The spring chamber is vented to atmosphere, which is internally O-ring sealed from the cartridge flow paths.On remote pilot signal at port ①, the valve's spool shifts to open port ③ to ④,while port ② is blocked.Because of the vented spring chamber, the cartridge may be fully pressurized at any port without affecting required pilot pressure.
-
PerformanceCurves
-
Technical Data
250barSee PRESSURE DROP VS.FLOW graph.10-4Refer to "Cleanliness of Hydraulic Fluid"82cc/min.max. at 250barTo Full Spool Shift:
(for 4.1bar spring): 4.7bar
(for 7.6bar spring): 8.6bar-40ºF to +250ºF(-40ºC to +120ºC)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES