- 4-Way 2-Position
- 2-Way 2-Position 3-Way 2-Position 4-Way 2-Position 4-Way 3-Position 5-Way 3-Position
Up all
Pack up all
-
Technical Feature
OPERATION:
When de-energized, the valve flows paths are blocked. When energized, the
cartridge's spool shifts to allow flow from ③ to ④ or from ④ to ③ and from ② to ① or
from ① to ②.Operation of Manual Override Option:
To override, push button in, twist counterclockwise 180°and release. In this position,
valve will remain detented in the shifted condition. To return to normal operation, push
button in, twist clockwise 180°and release. Override will be detented in this position. -
PerformanceCurves
-
Technical Data
207barSee PRESSURE DROP VS.FLOW graph.10-4Refer to "Cleanliness of Hydraulic Fluid"82 cc/min.max. at 207bar-40ºF to +212ºF(-40ºC to +100ºC)Continuous from 85% to 115% of nominal voltageMineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated at 207Bar, Steel & Ductile iron rated at 350Bar -
File Download
PDF File -
ACCESSORIES
CoilAccessories