LSV6-08-2 RNORP

PDF Download

Description

A solenoid operated, 2-way, 2-position, normally open, poppettype cartridge valve with reverse flow de-energized.

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    When de-energized, the poppet lifts to open flow from to ; Flow is also open
    from
    to .
    When energized ,the cartridge acts as a check valve, allowing flow from
    to , while
    blocking flow from
    to , after overcoming the solenoid force.


    Operation of Manual Override Option:

    To override, push button in to activate. To return to normal valve function, release button.

  • PerformanceCurves

    4.png

  • Technical Data

    Operating Pressure
    350bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    08-2
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    3drops/min.max. at 350bar
    Temperature
    -40ºF to +212ºF(-40ºC to +100ºC)
    Coil Duty Rating
    Continuous from 85% to 115% of nominal voltage
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    6061-T6 aluminum alloy rated at 207Bar, Steel & Ductile iron rated at 350Bar
  • File Download

    PDF File
  • ACCESSORIES

    Coil
    Accessories
Contact Us