LM-SQ-30-G12

PDF Download

Description

An in-line, adjustable directacting sequence valve with internal pilot and drain

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    Pressure at C1 overcomes the spring-bias pressure 1.1 bar and allows free flow to V1, V1 pressure
    increases to meet the valve setting, allow flow from V1 to C1.


  • PerformanceCurves

    ll.png

  • Technical Data

    Operating Pressure
    350Bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    5 drops/min max at 350bar
    Standard Spring Ranges
    30 to 120bar
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.