LBRV2-10

PDF Download

Description

A cartridge-style direct-acting bidirectional relief valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    The valve is a direct-acting, dual cross-over relief valve in a single cartridge format.
    When pressure at either port exceeds the nominal setting value, flow will be transmitted
    to the opposite port. Back pressure at either port will affect the nominal setting of the
    opposite port on a 1 :1 basis.
    For correlation purposes, pre-set value will be measured at port
    .Pressure at port
    will not exceed ±150 psi from the port value.

  • PerformanceCurves

    ll.png

  • Technical Data

    Operating Pressure
    240Bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    10-2
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    when reseat to 85% of Cracking Pressure: 33 ml/min
    Reseat Pressure
    80% of cracking pressure (cracking pressure at 0.95 lpm /0.25 gpm)
    Maximum Difference for Crack Pressure in Both Directions
    10.5 bar (150 psi)
    Standard Spring Ranges
    Pressure is set at port② , 20 to 168 bar; Preset: 69bar
    100 to 210 bar; Preset: 138bar
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar
  • File Download

    PDF File
  • ACCESSORIES