OPERATION:
The valve allows flow from ② to ① , while normally blocking flow from ① to ② . Flow will be allowed from ① to ② when sufficient pressure is applied at ③.
The cartridge has a 3:1 pilot ratio, meaning that at least one-third of the load pressure held at ① is required at ③ to open the valve.
-
PerformanceCurves
-
Technical Data
Operating Pressure350BarFlowSee PRESSURE DROP VS.FLOW graph.Cavity10-3SFiltrationRefer to "Cleanliness of Hydraulic Fluid"Internal Leakage2 drops/min. max. at 350barCrack Pressures0.3=0.3bar
2.0=2.0bar
5.1=5.1bar
6.9=6.9barPilot Ratio3:01Temperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body MaterialSteel & Ductile iron rated to 350bar -