Up all
Pack up all
-
Technical Feature
OPERATION:
The valve allows flow from ② to ③ , while normally blocking flow from ③ to ② . Flow will be allowed from ③ to ② when sufficient pressure is applied at ①.
The cartridge has a 3:1 pilot ratio, meaning that at least one-third of the load pressure held at ③ is required at ① to open the valve.
-
PerformanceCurves
-
Technical Data
250BarSee PRESSURE DROP VS.FLOW graph.08-3Refer to "Cleanliness of Hydraulic Fluid"③to②: 3 drops/min. (0.15 ml/min.) at 250bar
②to①with sealed piston: zero leakage1.7=1.7bar
2.1=2.1bar
5.2=5.2bar
6.2=6.2bar
8.2=8.2bar
18.3=18.3bar3:01-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES