Up all
Pack up all
-
Technical Feature
OPERATION:
Pressure at ① overcomes the spring-bias poppet and allows free flow from ① to ② .
Flow in the opposite direction, from ② to ① ,is blocked by the poppet. -
PerformanceCurves
-
Technical Data
Operating Pressure250barFlowSee PRESSURE DROP VS.FLOW graph.Cavity12-2FiltrationRefer to "Cleanliness of Hydraulic Fluid"Internal Leakage5 drops/min max. at 250barCrack Pressures1.7=1.7bar
4.5=4.5barTemperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body Material6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES